会议论文详细信息
FAIRNESS 2016
Conception and design of a control and monitoring system for the mirror alignment of the CBM RICH detector
Bendarouach, J.^1
Justus-Liebig-University Giessen, Germany^1
关键词: Compressed baryonic matters;    Control and monitoring systems;    Detector components;    Electron identification;    Mirror misalignment;    Moderate temperature;    Quantitative method;    Ring Imaging Cherenkov detector;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/742/1/012007/pdf
DOI  :  10.1088/1742-6596/742/1/012007
来源: IOP
PDF
【 摘 要 】

The Compressed Baryonic Matter (CBM) experiment at the future Facility for Anti-proton and Ion Research (FAIR) complex will investigate the phase diagram of strongly interacting matter at high baryon density and moderate temperatures created in A+A collisions. For the SIS100 accelerator, the foreseen beam energy will range up to 11 AGeV for the heaviest nuclei. One of the key detector components required for the CBM physics program is the Ring Imaging CHerenkov (RICH) detector, which is developed for efficient and clean electron identification and pion suppression. An important aspect to guarantee a stable operation of the RICH detector is the alignment of the mirrors. A qualitative alignment control procedure for the mirror system has been implemented in the CBM RICH prototype detector and tested under real conditions at the CERN PS/T9 beamline. Collected data and results of image processing are reviewed and discussed. In parallel a quantitative method using recorded data has also been employed to compute mirror displacements of the RICH mirrors. Results based on simulated events and the limits of the method are presented and discussed as well. If mirror misalignment is detected, it can be subsequently included and rectified by correction routines. A first correction routine is presented and a comparison between misaligned, corrected and ideal geometries is shown.

【 预 览 】
附件列表
Files Size Format View
Conception and design of a control and monitoring system for the mirror alignment of the CBM RICH detector 2918KB PDF download
  文献评价指标  
  下载次数:30次 浏览次数:36次