6th Asian Physics Symposium | |
Design and Implementation of Automatic Air Flow Rate Control System | |
Akbar, A.^1 ; Saputra, C.^1 ; Munir, M.M.^1,3 ; Khairurrijal^2,3 | |
Theoretical High Energy and Instrumentation Research Division, Indonesia^1 | |
Physics of Electronics Material Research Division, Faculty of Mathematics and Natural Sciences, Indonesia^2 | |
Research Center for Bioscience and Biotechnology, Institut Teknologi Bandung, Jalan Ganesa 10, Bandung | |
40132, Indonesia^3 | |
关键词: 8-bit microcontrollers; Air flow-rate; Design and implementations; Differential pressure sensor; Graphical user interfaces (GUI); Motor rotation; Optimal parameter; Stepper motor; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/739/1/012011/pdf DOI : 10.1088/1742-6596/739/1/012011 |
|
来源: IOP | |
【 摘 要 】
Venturimeter is an apparatus that can be used to measure the air flow rate. In this experiment we designed a venturimeter which equipped with a valve that is used to control the air flow rate. The difference of pressure between the cross sections was measured with the differential pressure sensor GA 100-015WD which can calculate the difference of pressures from 0 to 3737.33 Pa. A 42M048C Z36 stepper motor was used to control the valve. The precision of this motor rotation is about 0.15 °. A Graphical User Interface (GUI) was developed to monitor and set the value of flow rate then an 8-bit microcontroller was used to process the control system In this experiment- the venturimeter has been examined to get the optimal parameter of controller. The results show that the controller can set the stable output air flow rate.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Design and Implementation of Automatic Air Flow Rate Control System | 1020KB | download |