会议论文详细信息
8th Brazilian Congress on Metrology
Development and evaluation of a technique for in vivo monitoring of 60Co in human lungs
De Mello, J.Q.^1 ; Lucena, E.A.^1 ; Dantas, A.L.A.^1 ; Dantas, B.M.^1
Instituto de Radioproteção e Dosimetria-CNEN, Brazil^1
关键词: Accidental intakes;    Dosimetric models;    Effective dose;    Human bodies;    Human lung;    Internal exposure;    Minimum detectable activities;    Occupational exposure;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/733/1/012089/pdf
DOI  :  10.1088/1742-6596/733/1/012089
来源: IOP
PDF
【 摘 要 】

60Co is a fission product of235U and represents a risk of internal exposure of workers in nuclear power plants, especially those involved in the maintenance of potentially contaminated parts and equipment. The control of60Co intake by inhalation can be performed through in vivo monitoring. This work describes the evaluation of a technique through the minimum detectable activity and the corresponding minimum detectable effective doses, based on biokinetic and dosimetric models of60Co in the human body. The results allow to state that the technique is suitable either for monitoring of occupational exposures or evaluation of accidental intake.

【 预 览 】
附件列表
Files Size Format View
Development and evaluation of a technique for in vivo monitoring of 60Co in human lungs 915KB PDF download
  文献评价指标  