Quality assurance of absorbed energy in Charpy impact test
Rocha, C.L.F.^1 ; Fabricio, D.A.K.^1 ; Costa, V.M.^1 ; Reguly, A.^1
Physical Metallurgy Laboratory (LAMEF), Federal University of Rio Grande Do sul, 99 Osvaldo Aranha Avenue, Porto Alegre, Rio Grande do Sul, Brazil^1
关键词: Absorbed energy;    ANOVA (analysis of variance);    Charpy tests;    Intralaboratory studies;    Normalized errors;    Standard requirements;    Statistical techniques;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/733/1/012009/pdf
DOI  :  10.1088/1742-6596/733/1/012009
来源: IOP
PDF
【 摘 要 】

In order to ensure the quality assurance and comply with standard requirements, an intralaboratory study has been performed for impact Charpy tests, involving two operators. The results based on ANOVA (Analysis of Variance) and Normalized Error statistical techniques pointed out that the execution of the tests is appropriate, because the implementation of quality assurance methods showed acceptable results.

【 预 览 】
附件列表
Files Size Format View
Quality assurance of absorbed energy in Charpy impact test 759KB PDF download