会议论文详细信息
8th Symposium on Frequency Standards and Metrology 2015 | |
Design of an ultra-compact reference ULE cavity | |
Didier, Alexandre^1 ; Millo, Jacques^1 ; Lacroûte, Clément^1 ; Ouisse, Morvan^1 ; Delporte, Jérôme^2 ; Giordano, Vincent^1 ; Rubiola, Enrico^1 ; Kersalé, Yann^1 | |
FEMTO-ST, CNRS/UBFC/ENSMM/UFC/UTBM, Besançon, France^1 | |
CNES, Toulouse, France^2 | |
关键词: Fractional frequencies; Relative sensitivity; Ultra-stable lasers; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/723/1/012029/pdf DOI : 10.1088/1742-6596/723/1/012029 |
|
来源: IOP | |
【 摘 要 】
This article presents the design and the conception of an ultra-compact Fabry-Pérot cavity which will be used to develop an ultra-stable laser. The proposed cavity is composed of a 25 mm long ULE spacer with fused silica mirrors. It leads to an expected fractional frequency stability of 1.5 × 10-15limited by the thermal noise. The chosen geometry leads to an acceleration relative sensitivity below 10-12/(m/s2) for all directions.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Design of an ultra-compact reference ULE cavity | 1911KB | download |