会议论文详细信息
14th International Conference on Topics in Astroparticle and Underground Physics
Measuring the 14C content in liquid scintillators
物理学;天文学
Enqvist, T.^1 ; Barabanov, I.R.^2 ; Bezrukov, L.B.^2 ; Gangapshev, A.M.^2 ; Gavrilyuk, Y.M.^2 ; Yu Grishina, V.^2 ; Gurentsov, V.I.^2 ; Hissa, J.^1 ; Joutsenvaara, J.^1 ; Kazalov, V.V.^2 ; Krokhaleva, S.^2 ; Kutuniva, J.^1 ; Kuusiniemi, P.^1 ; Kuzminov, V.V.^2 ; Kurlovich, A.S.^2 ; Loo, K.^3 ; Lubsandorzhiev, B.K.^2 ; Lubsandorzhiev, S.^2 ; Morgalyuk, V.P.^2 ; Novikova, G.Y.^2 ; Pshukov, A.M.^2 ; Sinev, V.V.^2 ; Slupecki, M.^2 ; Trzaska, W.H.^2 ; Umerov, Sh.I.^2 ; Veresnikova, A.V.^2 ; Virkajärvi, A.^1 ; Yanovich, Y.A.^2 ; Zavarzina, V.P.^2
Oulu Southern Institute, Department of Physics, University of Oulu, Finland^1
Institute for Nuclear Research, Russian Academy of Sciences, Moscow, Russia^2
Department of Physics, University of Jyväskylä, Finland^3
关键词: Finland;    Gas sources;    Liquid scintillator;    Local environments;    Low energy neutrinos;    Simulation packages;    Underground laboratory;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/718/6/062018/pdf
DOI  :  10.1088/1742-6596/718/6/062018
学科分类:天文学(综合)
来源: IOP
PDF
【 摘 要 】

We are going to perform a series of measurements where the14C/12C ratio will be measured from several liquid scintillator samples with a dedicated setup. The setup is designed with the aim of measuring ratios smaller than 10-18. Measurements take place in two underground laboratories: in the Baksan Neutrino Observatory, Russia and in the Pyhäsalmi mine, Finland. In Baksan the measurements started in 2015 and in Pyhäsalmi they start in the beginning of 2015. In order to fully understand the operation of the setup and its background contributions a development of simulation packages has also been started. Low-energy neutrino detection with a liquid scintillator requires that the intrinsic14C content in the liquid is extremely low. In the Borexino CTF detector at Gran Sasso, Italy the14C/12C ratio of 2 × 10-18has been achieved being the lowest14C concentration ever measured. In principle, the older the oil or gas source that the liquid scintillator is derived of and the deeper it situates, the smaller the14C/12C ratio is supposed to be. This, however, is not generally the case, and the ratio is probably determined by the U and Th content of the local environment.

【 预 览 】
附件列表
Files Size Format View
Measuring the 14C content in liquid scintillators 807KB PDF download
  文献评价指标  
  下载次数:17次 浏览次数:37次