会议论文详细信息
13th South-East Asian Congress of Medical Physics 2015
Eye dose to staff involved in interventional and procedural fluoroscopy
物理学;医药卫生
McLean, D.^1 ; Hadaya, D.^1 ; Tse, J.^1
Medical Physics and Radiation Engineering, Canberra Hospital, Garran
ACT, Australia^1
关键词: Clinical procedure;    Close proximity;    Dose measurement;    Endoscopic retrograde cholangiopancreatography;    International commission on radiological protections;    Interventional procedures;    Medical physicists;    Personal protective equipment;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/694/1/012054/pdf
DOI  :  10.1088/1742-6596/694/1/012054
学科分类:卫生学
来源: IOP
PDF
【 摘 要 】
In 2011 the International Commission on Radiological Protection (ICRP) lowered the occupational eye dose limit from 150 to 20 mSv/yr [1]. While international jurisdictions are in a process of adopting these substantial changes, medical physicists at the clinical level have been advising medical colleagues on specific situations based on dose measurements. Commissioned and calibrated TLDs mounted in commercially available holders designed to simulate the measurement of Hp(3), were applied to staff involved in x-ray procedures for a one month period. During this period clinical procedure data was concurrently collected and subject to audit. The use or not of eye personal protective equipment (PPE) was noted for all staff. Audits were conducted in the cardiac catheterisation laboratory, the interventional angiography rooms and the procedural room where endoscopic retrograde cholangiopancreatography (ERCP) procedures are performed. Significant levels of occupational dose were recorded in the cardiac and interventional procedures, with maximum reading exceeding the new limit for some interventional radiologists. No significant eye doses were measured for staff performing ERCP procedures. One outcome of the studies was increased use of eye PPE for operators of interventional equipment with increased availability also to nursing staff, when standing in close proximity to the patient during procedures.
【 预 览 】
附件列表
Files Size Format View
Eye dose to staff involved in interventional and procedural fluoroscopy 870KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:38次