会议论文详细信息
13th South-East Asian Congress of Medical Physics 2015
Verification of Oncentra brachytherapy planning using independent calculation
物理学;医药卫生
Safian, N.A.M.^1 ; Abdullah, N.H.^1 ; Abdullah, R.^1 ; Chiang, C.S.^1
Medical Radiation Programme, School of Health Sciences, Health Campus, Universiti Sains Malaysia, Kubang Kerian, Kelantan
16150, Malaysia^1
关键词: Brachytherapy;    Calculation software;    High-dose-rate brachytherapy;    Point coordinates;    Source strength;    Treatment planning systems;    Treatment plans;    Verification techniques;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/694/1/012003/pdf
DOI  :  10.1088/1742-6596/694/1/012003
学科分类:卫生学
来源: IOP
PDF
【 摘 要 】

This study was done to investigate the verification technique of treatment plan quality assurance for brachytherapy. It is aimed to verify the point doses in192Ir high dose rate (HDR) brachytherapy between Oncentra Masterplan brachytherapy treatment planning system and independent calculation software at a region of rectum, bladder and prescription points for both pair ovoids and full catheter set ups. The Oncentra TPS output text files were automatically loaded into the verification programme that has been developed based on spreadsheets. The output consists of source coordinates, desired calculation point coordinates and the dwell time of a patient plan. The source strength and reference dates were entered into the programme and then dose point calculations were independently performed. The programme shows its results in a comparison of its calculated point doses with the corresponding Oncentra TPS outcome. From the total of 40 clinical cases that consisted of two fractions for 20 patients, the results that were given in term of percentage difference, it shows an agreement between TPS and independent calculation are in the range of 2%. This programme only takes a few minutes to be used is preferably recommended to be implemented as the verification technique in clinical brachytherapy dosimetry.

【 预 览 】
附件列表
Files Size Format View
Verification of Oncentra brachytherapy planning using independent calculation 892KB PDF download
  文献评价指标  
  下载次数:38次 浏览次数:31次