会议论文详细信息
8th International Conference on Inertial Fusion Sciences and Applications
Orion: a high contrast user facility
Hillier, D.I.^1 ; Danson, C.N.^1 ; Duffield, S.J.^1 ; Egan, D.A.^1 ; Elsmere, S.P.^1 ; Girling, M.T.^1 ; Harvey, E.J.^1 ; Hopps, N.W.^1 ; Norman, M.J.^1 ; Parker, S.J.F.^1 ; Treadwell, P.T.^1 ; Winter, D.N.^1 ; Bett, T.H.^1
Plasma Physics Technology Centre, AWE, Aldermaston, Reading
RG7 4PR, United Kingdom^1
关键词: Chirped pulse amplifications;    First harmonic;    Further works;    High contrast;    Long pulse;    Shaped pulse;    Sub-apertures;    Synchronized laser;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/688/1/012030/pdf
DOI  :  10.1088/1742-6596/688/1/012030
来源: IOP
PDF
【 摘 要 】

The Orion facility consists of two synchronized laser systems: two CPA (Chirped Pulse Amplification) beamlines each deliver 500J to target in a 0.5ps pulse (1PW) at 1054nm; and ten long pulse beamlines each deliver 500J in 0.1-5ns temporally shaped pulse at 351nm. One of the CPA beamlines has the option to be frequency doubled at sub-aperture to produce 100J laser pulses with a nanosecond contrast of ∼ 1014. Further work is under way to enhance the contrast of both CPA beamlines in the first harmonic.

【 预 览 】
附件列表
Files Size Format View
Orion: a high contrast user facility 1061KB PDF download
  文献评价指标  