会议论文详细信息
International Conference on Particle Physics and Astrophysics | |
Liquid-xenon detector under the intensive pulse irradiation conditions | |
Kirsanov, M.A.^1 | |
National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Kashirskoe highway 31, Moscow | |
115409, Russia^1 | |
关键词: Absorbed dose; Liquid xenon; Pulse irradiation; Pulsed irradiation; Stable operation; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/675/4/042014/pdf DOI : 10.1088/1742-6596/675/4/042014 |
|
来源: IOP | |
【 摘 要 】
The effect of intense pulsed irradiation on the operation of the liquid xenon spectrometer was studied. The ionization chamber filled with liquid xenon was irradiated by bremsstrahlung pulses of the microtron. The pulse repetition rate was 400 Hz. The absorbed dose ranged from 10-7to 0.1 Gy per pulse. Stable operation of the liquid xenon spectrometer in the intervals between the pulses of the accelerator was shown for a long time.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Liquid-xenon detector under the intensive pulse irradiation conditions | 831KB | download |