会议论文详细信息
9th International Conference on Modern Techniques of Plasma Diagnostics and their Application
Diagnostics of beam plasma produced in dielectric cavity at fore-vacuum pressures
Zolotukhin, D.^1
Tomsk State University of Control Systems and Radioelectronics, Lenina prospect, 40, Tomsk
634050, Russia^1
关键词: Axial distribution;    Continuous injections;    Dielectric cavities;    Floating potentials;    Optical measurement;    Plasma concentration;    Plasma parameter;    Vacuum pressure;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/666/1/012035/pdf
DOI  :  10.1088/1742-6596/666/1/012035
来源: IOP
PDF
【 摘 要 】

The results of the probe and optical measurements of plasma parameters produced during the injection of the electron beam with the energy of 3-8 keV and current of 30-60 mA into a dielectric cavity at the argon pressure of 2-12 Pa are presented. The possibility of continuous injection of the electron beam into the cavity without current-collecting electrodes inside is demonstrated. The axial distribution of the values of the plasma parameters (density, electron temperature and floating potential) in the cavity is discussed. The plasma concentration in the cavity is shown to be approximately 20% higher, and the electron temperature 1.5-2 times higher, than in the case of generating the plasma in the free space of the vacuum chamber.

【 预 览 】
附件列表
Files Size Format View
Diagnostics of beam plasma produced in dielectric cavity at fore-vacuum pressures 1268KB PDF download
  文献评价指标  
  下载次数:44次 浏览次数:34次