会议论文详细信息
9th International Symposium on Cavitation
Finite Volume Computation of the Mitigation of Cavity Pulsation
Lindau, J.^1 ; Skidmore, G.^1 ; Brungart, T.^1 ; Moeny, M.^1 ; Kinzel, M.^1
Penn State Applied Research Lab, PO Box 30, State College
PA
16804-0030, United States^1
关键词: Cavity pulsation;    Cavity size;    Mass flow rate;    Numerical approaches;    Sinusoidal modulation;    Ventilated supercavity;    Ventilation flow;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/656/1/012158/pdf
DOI  :  10.1088/1742-6596/656/1/012158
来源: IOP
PDF
【 摘 要 】

Finite volume based modeling of ventilated supercavity pulsation and its mitigation via a priori modulation of ventilation flow was investigated. Simulated pulsation was numerically achieved, as was mitigation of pulsation via sinusoidal modulation of the ventilation flow. In addition to confirmation that the numerical approach is sufficient to capture mitigation, it was found that modulated ventilation, without altering the mean ventilation mass flow rate, results in altered cavity size, pressure, and closure condition.

【 预 览 】
附件列表
Files Size Format View
Finite Volume Computation of the Mitigation of Cavity Pulsation 1034KB PDF download
  文献评价指标  
  下载次数:20次 浏览次数:15次