会议论文详细信息
9th International Symposium on Cavitation
Predicting the Inception Cavitation of a Reversible Pump- Turbine in Pump Mode
Tao, Ran^1 ; Xiao, Ruofu^1 ; Zhu, Di^1 ; Liu, Weichao^2
College of Water Resources and Civil Engineering, China Agricultural University, Beijing
100083, China^1
Dongfang Electric Machinery Co., LTD, Deyang, Sichuan Province
618000, China^2
关键词: Cavitation number;    CFD simulations;    Inception cavitations;    Reversible pump-turbine;    Vapor volume fraction;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/656/1/012077/pdf
DOI  :  10.1088/1742-6596/656/1/012077
来源: IOP
PDF
【 摘 要 】

Inception cavitation is a crucial indicator for reversible pump-turbines especially in pump mode. In actual applications, it is difficult to use CFD for the inception cavitation character. In this study, CFD simulation is conducted to find a proper way to evaluate the inception cavitation, different levels of vapor volume fraction in the impeller is predicted based on the tested results. Results show that the prediction of the location and scale of cavitation is accurate. The predicted cavitation number also matches the experimental data well. The vapor volume fraction levels from 0.0001% to 0.001% are recommended as the criterion of inception cavitation.

【 预 览 】
附件列表
Files Size Format View
Predicting the Inception Cavitation of a Reversible Pump- Turbine in Pump Mode 1142KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:16次