会议论文详细信息
International Conference on Bio-Medical Instrumentation and related Engineering and Physical Sciences
The electromagnetic environment of Magnetic Resonance Imaging systems. Occupational exposure assessment reveals RF harmonics
物理学;医药卫生
Gourzoulidis, G.^1,3 ; Karabetsos, E.^2 ; Skamnakis, N.^2 ; Kappas, C.^3 ; Theodorou, K.^3 ; Tsougos, I.^3 ; Maris, T.G.^4
Hazardous Agents Dep., Hellenic Ministry of Labor, 29 Stadiou str., GR10110, Greece^1
Greek Atomic Energy Commission, Non-Ionizing Rad. Off., POBox60092, GR15310, Greece^2
Department of Medical Physics, University of Thessaly, Larissa
GR41500, Greece^3
Department of Medical Physics, University of Crete, POBox1352, GR71201, Greece^4
关键词: Electromagnetic environments;    Electromagnetic field (EMF);    Electromagnetic field exposure;    Low and high frequencies;    Magnetic Resonance Imaging (MRI);    Occupational exposure assessments;    Occupational health and safety;    Static magnetic fields;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/637/1/012009/pdf
DOI  :  10.1088/1742-6596/637/1/012009
学科分类:卫生学
来源: IOP
PDF
【 摘 要 】

Magnetic Resonance Imaging (MRI) systems played a crucial role in the postponement of the former occupational electromagnetic fields (EMF) European Directive (2004/40/EC) and in the formation of the latest exposure limits adopted in the new one (2013/35/EU). Moreover, the complex MRI environment will be finally excluded from the implementation of the new occupational limits, leading to an increased demand for Occupational Health and Safety (OHS) surveillance. The gradient function of MRI systems and the application of the RF excitation frequency result in low and high frequency exposures, respectively. This electromagnetic field exposure, in combination with the increased static magnetic field exposure, makes the MRI environment a unique case of combined EMF exposure. The electromagnetic field levels in close proximity of different MRI systems have been assessed at various frequencies. Quality Assurance (QA) & safety issues were also faced. Preliminary results show initial compliance with the forthcoming limits in each different frequency band, but also revealed peculiar RF harmonic components, of no safety concern, to the whole range detected (20-1000MHz). Further work is needed in order to clarify their origin and characteristics.

【 预 览 】
附件列表
Files Size Format View
The electromagnetic environment of Magnetic Resonance Imaging systems. Occupational exposure assessment reveals RF harmonics 967KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:31次