会议论文详细信息
37th Brazilian Meeting on Nuclear Physics
Evaluation of Microstructural Parameters of Reservoir Rocks of the Guarani Aquifer by Analysis of Images Obtained by X- Ray Microtomography
Fernandes, J.S.^1 ; Lima, F.A.^1 ; Vieira, S.F.^1 ; Reis, P.J.^2 ; Appoloni, C.R.^2
Instituto Federal de Educação, Ciência e Tecnologia Catarinense - IFC, Câmpus Videira SC-135, Km 125, Campo Experimental, Videira, Santa-Catarina
CEP 89560-000, Brazil^1
Laboratório de Física Nuclear Aplicada, Departamento de Física, Universidade Estadual de Londrina - UEL, CP 6001, Paraná, Londrina
CEP 86051-990, Brazil^2
关键词: Internal structure;    Micro-structural characterization;    Microstructural parameters;    Nondestructive methods;    Physics laboratories;    Space resolutions;    Water industries;    X ray microtomography;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/630/1/012008/pdf
DOI  :  10.1088/1742-6596/630/1/012008
来源: IOP
PDF
【 摘 要 】

Microstructural parameters evaluation of porous materials, such as, rocks reservoir (water, petroleum, gas...), it is of great importance for several knowledge areas. In this context, the X-ray microtomography (μ-CT) has been showing a technical one quite useful for the analysis of such rocks (sandstone, limestone and carbonate), object of great interest of the petroleum and water industries, because it facilitates the characterization of important parameters, among them, porosity, permeability, grains or pore size distribution. The X-ray microtomography is a non-destructive method, that besides already facilitating the reuse of the samples analyzed, it also supplies images 2-D and 3-D of the sample. In this work samples of reservoir rock of the Guarani aquifer will be analyzed, given by the company of perforation of wells artesian Blue Water, in the municipal district of Videira, Santa Catarina, Brazil. The acquisition of the microtomographys data of the reservoir rocks was accomplished in a Skyscan 1172 μ-CT scanner, installed in Applied Nuclear Physics Laboratory (LFNA) in the State University of Londrina (UEL), Paraná, Brazil. In this context, this work presents the microstructural characterization of reservoir rock sample of the Guarani aquifer, analyzed for two space resolutions, 2.8 μm and 4.8 μm, where determined average porosity was 28.5% and 21.9%, respectively. Besides, we also determined the pore size distribution for both resolutions. Two 3-D images were generated of this sample, one for each space resolution, in which it is possible to visualize the internal structure of the same ones.

【 预 览 】
附件列表
Files Size Format View
Evaluation of Microstructural Parameters of Reservoir Rocks of the Guarani Aquifer by Analysis of Images Obtained by X- Ray Microtomography 1367KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:16次