会议论文详细信息
15th Latin American Workshop on Plasma Physics; 21st IAEA TM on Research Using Small Fusion Devices
Study of N2/He DC glow discharge
Villa, M.^1 ; Flores, O.^2 ; Castillo, F.^2 ; Reyes, P.G.^1 ; Martinez, H.^2
Facultad de Ciencias, Universidad Autónoma Del Estado de México, Estado de México, Mexico^1
Laboratorio de Espectroscopia, Instituto de Ciencias Físicas, Universidad Nacional Autónoma de México, Apartado Postal 48-3, Morelos, Cuernavaca
62251, Mexico^2
关键词: DC glow discharge;    Emission bands;    Spectrometry measurements;    Total pressure;    Wavelength ranges;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/591/1/012067/pdf
DOI  :  10.1088/1742-6596/591/1/012067
来源: IOP
PDF
【 摘 要 】

Optical emission spectroscopy and mass spectrometry measurement were used to study a gas mixture glow discharge of He and N2at total pressure of 2.0 Torr, a power of 10 W and a flow of 16.5 l/min. The emission bands were measured in the wavelength range of 200 to 1100 nm. The principal species observed were N2+(B2Σ+u→X2Σ+g), N2(C3Πu→B3Πg), and He, which agree with mass spectrometry measurement.

【 预 览 】
附件列表
Files Size Format View
Study of N2/He DC glow discharge 910KB PDF download