会议论文详细信息
16th International Conference on Calorimetry in High Energy Physics | |
New Fast Shower Max Detector Based on MCP as an Active Element | |
Ronzhin, A.^1 ; Los, S.^1 ; Ramberg, E.^1 ; Spiropulu, M.^2 ; Apresyan, A.^2 ; Xie, S.^2 ; Kim, H.^3 ; Zatserklyaniy, A.^4 | |
Fermilab, Batavia | |
IL, United States^1 | |
California Institute of Technology, Pasadena | |
CA, United States^2 | |
University of Chicago, Chicago | |
IL, United States^3 | |
University of California, Santa Cruz | |
CA, United States^4 | |
关键词: Active elements; Detector response; Micro channel plate; Radiation resistant; Test beam; Time resolution; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/587/1/012058/pdf DOI : 10.1088/1742-6596/587/1/012058 |
|
来源: IOP | |
![]() |
【 摘 要 】
One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photo detectors based on micro channel plates (MCP) as secondary emitter. The SM time resolution-we obtained for this new type of detector is at the level of 20-30 ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
New Fast Shower Max Detector Based on MCP as an Active Element | 977KB | ![]() |