会议论文详细信息
16th International Conference on Calorimetry in High Energy Physics
New Fast Shower Max Detector Based on MCP as an Active Element
Ronzhin, A.^1 ; Los, S.^1 ; Ramberg, E.^1 ; Spiropulu, M.^2 ; Apresyan, A.^2 ; Xie, S.^2 ; Kim, H.^3 ; Zatserklyaniy, A.^4
Fermilab, Batavia
IL, United States^1
California Institute of Technology, Pasadena
CA, United States^2
University of Chicago, Chicago
IL, United States^3
University of California, Santa Cruz
CA, United States^4
关键词: Active elements;    Detector response;    Micro channel plate;    Radiation resistant;    Test beam;    Time resolution;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/587/1/012058/pdf
DOI  :  10.1088/1742-6596/587/1/012058
来源: IOP
PDF
【 摘 要 】

One possibility to make a fast and radiation resistant shower maximum (SM) detector is to use a secondary emitter as an active element. We present below test beam results, obtained with different types of photo detectors based on micro channel plates (MCP) as secondary emitter. The SM time resolution-we obtained for this new type of detector is at the level of 20-30 ps. We estimate that a significant contribution to the detector response originates from secondary emission of the MCP.

【 预 览 】
附件列表
Files Size Format View
New Fast Shower Max Detector Based on MCP as an Active Element 977KB PDF download
  文献评价指标  
  下载次数:22次 浏览次数:16次