会议论文详细信息
16th International Conference on Calorimetry in High Energy Physics
The CMS Outer HCAL SiPM Upgrade
Lobanov, Artur^1
Deutsches Elektronen-Synchrotron, Notkestrasse 85, Hamburg
D-22607, Germany^1
关键词: Hadron calorimeters;    Hadron colliders;    Peltier coolers;    Self triggers;    Temperature stabilization;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/587/1/012005/pdf
DOI  :  10.1088/1742-6596/587/1/012005
来源: IOP
PDF
【 摘 要 】

The CMS Outer Hadron Calorimeter (HO) is the first large scale hadron collider detector to use SiPMs. By late January 2014 the installation of 1656 of 2376 channels was completed. The HO readout system provides for active temperature stabilization of the SiPMs to less than 0.1°C using Peltier coolers, temperature measurement, and software feedback. Each channel has independently controlled bias voltage with a resolution of 25 mV. Each SiPM is read out by 40 MHz QIE ADCs. We report on the system design, schedule and progress. The next phase for the detector is commissioning during 2014 before the 2015 LHC run. We report on the status of commissioning and plans for operation. We discuss the calibration strategy with local cosmic ray runs using the HO's self trigger ability. We discuss the plans for a global CMS operations run in November 2014.

【 预 览 】
附件列表
Files Size Format View
The CMS Outer HCAL SiPM Upgrade 1651KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:27次