会议论文详细信息
| 7th Brazilian Congress on Metrology | |
| Determining camera parameters for round glassware measurements | |
| Baldner, F.O.^1,2 ; Costa, P.B.^1,2 ; Gomes, J.F.S.^2 ; Filho, D.M.E.S.^2 ; Leta, F.R.^1 | |
| Universidade Federal Fluminense-UFF, Programa de Pós-Graduação em Engenharia Mecânica, Laboratório de Metrologia Dimensional e Computacional, Rua Passo da Pátria 156, Niterói-Rio de Janeiro, Brazil^1 | |
| Instituto Nacional de Metrologia, Qualidade e Tecnologia-Inmetro, Av. Nossa Senhora das Graças, 50, Xerém-Duque de Caxias-Rio de Janeiro, Brazil^2 | |
| 关键词: Camera parameter; Digital single lens reflexes; Machine vision systems; Metrological quality; Quality image; | |
| Others : https://iopscience.iop.org/article/10.1088/1742-6596/575/1/012021/pdf DOI : 10.1088/1742-6596/575/1/012021 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
Nowadays there are many types of accessible cameras, including digital single lens reflex ones. Although these cameras are not usually employed in machine vision applications, they can be an interesting choice. However, these cameras have many available parameters to be chosen by the user and it may be difficult to select the best of these in order to acquire images with the needed metrological quality. This paper proposes a methodology to select a set of parameters that will supply a machine vision system with the needed quality image, considering the measurement required of a laboratory glassware.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Determining camera parameters for round glassware measurements | 1091KB |
PDF