Compact fluorescent lamps, LED lamps and harmonic distortion
Franco, A.M.R.^1 ; Debatin, R.M.^1 ; Cotia, F.C.G.^1 ; Silva, M.V.M.^1 ; Ribeiro, R.S.^1 ; Zampilis, R.R.N.^1
Electrical Energy Metrology Laboratory, Electrical Metrology Division, National Institute of Metrology, Quality and Technology-Inmetro, Av. Nossa Senhora das Graças, Xerém 50, Duque de Caxias, Brazil^1
关键词: Active power;    Compact fluorescent lamp;    LEd lamps;    Power factors;    Total Harmonic Distortion (THD);    Voltage waveforms;    Wave forms;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/575/1/012009/pdf
DOI  :  10.1088/1742-6596/575/1/012009
来源: IOP
PDF
【 摘 要 】

The aim of this paper is to evaluate the harmonic distortion in the current waveform of Compact Fluorescent Lamps (CFL) and Lamps Lighting Emitting Diode (LED). For this, we analysed the power factor, voltage waveform, current waveform, total harmonic distortion (THD) and active power consumed.

【 预 览 】
附件列表
Files Size Format View
Compact fluorescent lamps, LED lamps and harmonic distortion 928KB PDF download