| 8th International Conference on 3D Radiation Dosimetry | |
| Clinical applications of 3-D dosimeters | |
| Wuu, Cheng-Shie^1 | |
| Department of Radiation Oncology, Columbia University, New York | |
| NY, United States^1 | |
| 关键词: Brachytherapy; Clinical application; Critical organs; Dose distributions; Dose verification; Treatment modality; Treatment outcomes; Treatment techniques; | |
| Others : https://iopscience.iop.org/article/10.1088/1742-6596/573/1/012011/pdf DOI : 10.1088/1742-6596/573/1/012011 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
Both 3-D gels and radiochromic plastic dosimeters, in conjunction with dose image readout systems (MRI or optical-CT), have been employed to measure 3-D dose distributions in many clinical applications. The 3-D dose maps obtained from these systems can provide a useful tool for clinical dose verification for complex treatment techniques such as IMRT, SRS/SBRT, brachytherapy, and proton beam therapy. These complex treatments present high dose gradient regions in the boundaries between the target and surrounding critical organs. Dose accuracy in these areas can be critical, and may affect treatment outcome. In this review, applications of 3-D gels and PRESAGE dosimeter are reviewed and evaluated in terms of their performance in providing information on clinical dose verification as well as commissioning of various treatment modalities. Future interests and clinical needs on studies of 3-D dosimetry are also discussed.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Clinical applications of 3-D dosimeters | 2411KB |
PDF