会议论文详细信息
The Science of Making Torque from Wind 2012
Fatigue life prediction of rotor blade composites: Validation of constant amplitude formulations with variable amplitude experiments
Westphal, T.^1 ; Nijssen, R.P.L.^1
Knowledge Centre WMC, Kluisgat 5, Wieringerwerf
1771MV, Netherlands^1
关键词: Constant amplitude;    Constant life diagram;    Fatigue life prediction;    Prediction accuracy;    Variable amplitude fatigue;    Variable amplitudes;    Variable-amplitude experiments;    Wind turbine loading;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/555/1/012107/pdf
DOI  :  10.1088/1742-6596/555/1/012107
来源: IOP
PDF
【 摘 要 】

The effect of Constant Life Diagram (CLD) formulation on the fatigue life prediction under variable amplitude (VA) loading was investigated based on variable amplitude tests using three different load spectra representative for wind turbine loading. Next to the Wisper and WisperX spectra, the recently developed NewWisper2 spectrum was used. Based on these variable amplitude fatigue results the prediction accuracy of 4 CLD formulations is investigated. In the study a piecewise linear CLD based on the S-N curves for 9 load ratios compares favourably in terms of prediction accuracy and conservativeness. For the specific laminate used in this study Boerstra's Multislope model provides a good alternative at reduced test effort.

【 预 览 】
附件列表
Files Size Format View
Fatigue life prediction of rotor blade composites: Validation of constant amplitude formulations with variable amplitude experiments 829KB PDF download
  文献评价指标  
  下载次数:18次 浏览次数:36次