11th European Conference on Applied Superconductivity | |
Cryogen-free 1kA-class Ic measurement system featuring an 8 T HTS magnet | |
Strickland, N.M.^1 ; Hoffmann, C.^1,3 ; Wimbush, S.C.^1 ; Pooke, D.M.^2 ; Huang, T.^2 ; Lazic, Z.^2 ; Chamritski, V.^2 ; Talantsev, E.F.^1 ; Long, N.J.^1 ; Tallon, J.L.^1 | |
Callaghan Innovation, PO Box 31310, Lower Hutt | |
5040, New Zealand^1 | |
HTS-110 Ltd, PO Box 31310, Lower Hutt | |
5040, New Zealand^2 | |
Ceraco Ceramic Coating GmbH, Ismaning, Germany^3 | |
关键词: Conduction cooled; Field angle; Measurement system; Measuring systems; Metal organic; RABiTS substrates; Temperature rise; Transport currents; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/507/2/022037/pdf DOI : 10.1088/1742-6596/507/2/022037 |
|
来源: IOP | |
【 摘 要 】
We have developed a cryogen-free critical-current (Ic) measuring system comprising a conduction-cooled 8 T HTS magnet and convection-cooled sample, both cooled by commercial cryocoolers. The sample can be rotated and transport currents of up to 800 A delivered with less than 0.5 K temperature rise during the Ic measurement. The system is automated with respect to variations in temperature (30-90 K), field (0-8 T), and field angle (0-360°). We have used this system to measure HTS wire samples, concentrating on metal-organic deposited YBCO on RABiTS substrates. Particular emphasis is given to the evolution of Icanisotropy with temperature, and the dangers of extrapolating from 77 K to 30 K.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Cryogen-free 1kA-class Ic measurement system featuring an 8 T HTS magnet | 911KB | download |