18th APS-SCCM; 24th AIRAPT | |
Measurements of near-field blast effects using kinetic plates | |
Manner, V.W.^1 ; Pemberton, S.J.^1 ; Brown, G.W.^1 ; Tappan, B.C.^1 ; Hill, L.G.^1 ; Preston, D.N.^1 ; Neuscamman, S.J.^2 ; Glascoe, L.G.^2 | |
Los Alamos National Laboratory, Los Alamos | |
NM | |
87545, United States^1 | |
Lawrence Livermore National Laboratory, Livermore | |
CA | |
94550, United States^2 | |
关键词: Aluminized explosives; Blast effects; Cylinder tests; Experimental difficulties; Laser velocimetry; Measurements of; Non-ideal explosives; Size effects; | |
Others : https://iopscience.iop.org/article/10.1088/1742-6596/500/5/052029/pdf DOI : 10.1088/1742-6596/500/5/052029 |
|
来源: IOP | |
【 摘 要 】
Few tests have been designed to measure the near-field blast impulse of ideal and non-ideal explosives, mostly because of the inherent experimental difficulties due to non-transparent fireballs and thermal effects on gauges. In order to measure blast impulse in the near-field, a new test has been developed by firing spherical charges at 152 mm (6 in) from steel plates and probing acceleration using laser velocimetry. Tests measure the velocity imparted to the steel plate in the 50-300 μs timeframe, and are compared with free-field overpressure measurements at 1.52 m (5 ft) and ms timescales using piezoelectric pencil gauges. Specifically, tests have been performed with C4 to probe the contributions of ideal explosives and charge size effects. Non-ideal aluminized explosive formulations have been studied to explore the role of aluminum in near-field blast effects and far-field pressure, and are compared with formulations using LiF as an inert surrogate replacement for Al. The results are compared with other near-field blast tests and cylinder tests, and the validity of this test is explored with modeling and basic theory.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Measurements of near-field blast effects using kinetic plates | 2914KB | download |