会议论文详细信息
22nd International Congress on X-Ray Optics and Microanalysis
Ageing Effects on Exhaust Gas Catalysts: Microscopic Changes Captured by X-Ray Tomography
Hofmann, G.^1 ; Rochet, A.^1 ; Baier, S.^1 ; Casapu, M.^1 ; Ritter, S.^2 ; Wilde, F.^3 ; Ogurreck, M.^3 ; Beckmann, F.^3 ; Grunwaldt, J.-D.^1
Institute for Chemical Technology and Polymer Chemistry, Karlsruhe Institute of Technology, Karlsruhe, Germany^1
Institute of Structural Physics, Technical University Dresden, Dresden, Germany^2
Institute of Materials Research, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany^3
关键词: Ageing effects;    Ageing treatments;    Catalyst ageing;    Inhomogeneities;    Macro scale;    Micro computed tomography (micro-CT);    Non destructive;    X-ray tomography;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/499/1/012017/pdf
DOI  :  10.1088/1742-6596/499/1/012017
来源: IOP
PDF
【 摘 要 】

In this work we examine the different aspects of catalyst ageing with effects ranging from the nano to the macro scale. Underlining the general importance of combining different characterisation techniques, like transmission electron microscopy (TEM), X-ray absorption spectroscopy (XAS) and X-ray diffraction (XRD) for the nanoscale, we focus on the application of X-ray absorption micro-computed tomography (micro-CT) to capture macroscopic changes in the um to mm scale. Two series of tomographic measurements were carried out: (i) investigation of three differently treated samples by collecting one channel from a fresh, a conditioned and an aged monolith and (ii) examination of one single coated honeycomb channel with 4 wt% Pt/γ-Al2O3and for comparison one with pure γ-Al2O3washcoat, which have been measured in a non-destructive ex situ manner at the same position after each ageing treatment. Main observations of the tomographic study are: (1) coating inhomogeneities between different channels taken from the same honeycomb and between different honeycombs, (2) formation of cracks in the washcoat material and (3) formation of macroscopic Pt particles in the case of 4 wt% Pt/γ-Al2O3washcoat. Particularly valuable is the non-destructive ex situ investigation after different ageing steps on the same channel using X-ray tomography.

【 预 览 】
附件列表
Files Size Format View
Ageing Effects on Exhaust Gas Catalysts: Microscopic Changes Captured by X-Ray Tomography 3324KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:46次