会议论文详细信息
17th International Conference on the Use of Computers in Radiation Therapy
Streamlining EPID-based IMRT quality assurance: auto-analysis and auto-report generation
物理学;计算机科学
Xing, Aitang^1 ; Arumugam, Sankar^1 ; Deshpande, Shrikant^1,3 ; George, Armia^4 ; Holloway, Lois^1,2,3,4 ; Goozee, Gary^1,4 ; Gray, Alison^1 ; Vial, Philip^1,2
Liverpool and Macarthur Cancer Therapy Centres, Ingham Institute, Liverpool Hospital, Sydney, NSW, Australia^1
Institute of Medical Physics, School of Physics, University of Sydney, Sydney, NSW, Australia^2
Centre for Medical Radiation Physics, University of Wollongong, Wollongong, NSW, Australia^3
South Western Sydney Clinical School, University of New South Wales, Sydney, NSW, Australia^4
关键词: Automatically generated;    Commercial software;    Commercial software tools;    Patient specific;    Registered images;    Report generation;    Treatment planning systems;    Water equivalent;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/489/1/012084/pdf
DOI  :  10.1088/1742-6596/489/1/012084
学科分类:计算机科学(综合)
来源: IOP
PDF
【 摘 要 】
Using an EPID for patient specific IMRT QA is an efficient way to verify patient plans prior to the treatment. Our centres' current EPID dosimetry method is based on a water equivalent depth approach, where EPID images of each IMRT field are converted to dose images and compared to Treatment planning system calculated dose images using a commercial software tool. Two physicists across two sites perform the analysis for an average of 12 new IMRT patients per week. To speed up this process, an in-house program called AutoEPIDIMRTQA was developed. The program automatically performs the following tasks sequentially: reading and converting raw EPID images acquired on either a Siemens Oncor or Elekta Synergy linear accelerator, registering them with planar dose images calculated by Pinnacle (Philips) or CMS XiO (Elekta) treatment planning systems, analyzing the profiles for registered images and calculating the Gamma map. Finally an IMRT QA report is automatically generated. AutoEPIDIMRTQA was validated against commercial software. The analysis time for a typical 9-beam IMRT head-neck patient decreases from 30 minutes to 4 minutes. The total QA time was reduced by 40% using AutoEPIDIMRTQA. Thus we have demonstrated a significant reduction in the time burden for physics staff performing IMRT QA.