会议论文详细信息
14th International Conference on Metrology and Properties of Engineering Surfaces
Spikes removal in surface measurement
Podulka, P.^1 ; Pawlus, P.^1 ; Dobrzan´ski, P.^1 ; Lenart, A.^2
Rzeszow University of Technology, W. Pola 2, 35-959 Rzeszow, Poland^1
Pratt and Whitney AeroPower Rzeszów, Hetmanska 120, 35-078 Rzeszow, Poland^2
关键词: Cylinder surface;    Grey cast iron;    White-light interferometer;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/483/1/012025/pdf
DOI  :  10.1088/1742-6596/483/1/012025
来源: IOP
PDF
【 摘 要 】

Several cylinder surface topographies made from grey cast iron were measured by Talysurf CCI white light interferometer with and without use of spikes filter. They were plateau honed by abrasive stones. Measured area was 3.3 mm × 3.3 mm, height resolution was 0.01 nm. The forms were eliminated using polynomial of the 3rd degree. After it, spikes were removed using four methods. These approaches were compared. Parameters of the smaller and highest sensitivity on spikes presence were selected.

【 预 览 】
附件列表
Files Size Format View
Spikes removal in surface measurement 994KB PDF download
  文献评价指标  
  下载次数:23次 浏览次数:12次