会议论文详细信息
11th International Conference on X-ray Microscopy
Development of real-time x-ray microtomography system
Takano, H.^1 ; Morikawa, M.^1 ; Konishi, S.^1 ; Azuma, H.^1 ; Shimomura, S.^1 ; Tsusaka, Y.^1 ; Nakano, S.^2 ; Kosaka, N.^2 ; Yamamoto, K.^2 ; Kagoshima, Y.^1
Center for Novel Material Science under Multi-Extreme Conditions, Graduate School of Material Science, University of Hyogo, Kamigori, Hyogo 679-1297, Japan^1
NITTO DENKO Corporation, Umeda, Osaka 530-0001, Japan^2
关键词: High frame rate;    High-speed samples;    Real-time x-rays;    Synchrotron radiation x-rays;    System optimizations;    Voxel size;    X ray micro-computed tomography;    X-ray imagers;   
Others  :  https://iopscience.iop.org/article/10.1088/1742-6596/463/1/012025/pdf
DOI  :  10.1088/1742-6596/463/1/012025
来源: IOP
PDF
【 摘 要 】

We have developed a four-dimensional (4D) x-ray microcomputed tomography (CT) system that can obtain time-lapse CT volumes in real time. The system consists of a high-speed sample rotation system and a high-frame-rate x-ray imager, which are installed at a synchrotron radiation x-ray beamline. As a result of system optimization and introduction of a "zoom resolution" procedure, a real-time 4D CT movie with a frame rate of 30 was obtained with a voxel size of 2.5 μm using 10 keV x-rays.

【 预 览 】
附件列表
Files Size Format View
Development of real-time x-ray microtomography system 1379KB PDF download
  文献评价指标  
  下载次数:14次 浏览次数:26次