会议论文详细信息
2018 2nd International Conference on Power and Energy Engineering
Suppression Methods for Low Frequency Oscillation of Wind Farm Considering SVG Minimum Output Dead Zone
Zhang, Yangfan^1,2 ; Xie, Xu^3 ; Song, Peng^1,2 ; Liu, Hui^1,2 ; He, Tao^3
State Grid Jibei Electric Power Research Institute, North China Electric Power Research Institute Co. Ltd, Beijing, China^1
Grid-connected Opeartion Technol. for Wind-Solar-Storage Hybrid Syst. State Grid Corp. Key Lab., Beijing, China^2
State Grid Zhangjiakou Power Supply Company, Zhangjiakou, China^3
关键词: Automatic voltage control;    Electric field induced;    Low frequency oscillations;    Main circuit topologies;    Optimization modeling;    Optimization strategy;    Practical engineering applications;    Reactive power output;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/192/1/012043/pdf
DOI  :  10.1088/1755-1315/192/1/012043
来源: IOP
PDF
【 摘 要 】
At present, the research of Static Var Generator (SVG) mainly focuses on the main circuit topology, the optimization of control strategy, the method of selection, and lack of research on the low frequency oscillation of the wind farm caused by SVG minimum reactive output dead zone in practical engineering applications. For this reason, this paper first studies the mechanism of the low frequency oscillation of the wind electric field induced by the SVG minimum output dead zone of the wind farm, and discusses the conditions of this type of oscillation. On this basis, the automatic voltage control system (AVC) optimization model of wind farm is established with the minimum reactive variation of SVG output near the zero point as the optimization goal, and an optimization control strategy of wind farm with SVG minimum output reactive dead zone is proposed. Finally, the correctness of the result is verified by simulation. The results show that, due to the existence of the minimum output dead zone in the wind farm, the large reactive step may occur near the zero point of the SVG output, which causes the voltage low frequency oscillation of the wind farm. The optimization strategy proposed in this paper can significantly suppress the low frequency oscillation by coordinating and optimizing reactive power output near the zero point of multiple SVGs in wind farm.
【 预 览 】
附件列表
Files Size Format View
Suppression Methods for Low Frequency Oscillation of Wind Farm Considering SVG Minimum Output Dead Zone 764KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:11次