会议论文详细信息
2018 International Conference on Civil and Hydraulic Engineering
Test and Simulation of 9960Hz Subcarrier Modulation for DVOR Station of Civil Aviation
土木建筑工程;水利工程
Li, Yuankai^1 ; Wang, Bo^2 ; Liang, Fei^1 ; Li, Qingdong^1
Second Research Institute of CAAC, No. 17th South two of second ring road, Chengdu, Sichuan
610041, China^1
Southwest Regional Administration of CAAC, No. 8th Yun Ling Road, Shengli Town, Shuangliu district, Chengdu, Sichuan
610299, China^2
关键词: Field test;    Key factors;    Model simulation;    One-time;    Safety and efficiencies;    Sub-carrier modulations;    Test systems;    Three dimensional modelling;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/189/6/062007/pdf
DOI  :  10.1088/1755-1315/189/6/062007
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】

In order to solve the problem of 9960Hz subcarrier modulation of DVOR system exceeding the limit, this paper use the test system and three-dimensional modelling and simulation technology to ensure flight calibration passes smoothly. Taking an airport for example, the field test and modeling simulation are carried out in the same situation when the surrounding site and parameters are the same with the flight calibration, ensuring that the results are in good agreement with the flight calibration results. We can get that the substation is the key factor which affects the 9960Hz subcarrier modulation exceeding the limit. After removing the substation, 9960Hz subcarrier modulation meet the requirements, the airport pass the flight calibration one-time finally. This method solves the problem of the 9960Hz subcarrier modulation in a DVOR station and provides the reference basis for the problems encountered in the construction and operation of the navigation station, which ensuring the safety and efficiency of air transportation.

【 预 览 】
附件列表
Files Size Format View
Test and Simulation of 9960Hz Subcarrier Modulation for DVOR Station of Civil Aviation 1298KB PDF download
  文献评价指标  
  下载次数:9次 浏览次数:9次