2nd International Symposium on Resource Exploration and Environmental Science | |
Large scale 3D seepage analysis of whole pumped storage power station project area | |
生态环境科学 | |
Zhang, Hongwei^1,2 ; Shen, Zhenzhong^1,2 ; Tian, Meng^1,2 ; Cui, Zhiwei^3 | |
State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering, Hohai University, Nanjing, China^1 | |
Key Laboratory of Earth-Rock Dam Failure Mechanism and Safety Control Techniques, Ministry of Water Resources, Nanjing, China^2 | |
BGI Engineering Consultants Ltd, Beijing, China^3 | |
关键词: 3-D finite elements; Geological conditions; Hydrogeological conditions; Potential distributions; Pumped storage power station; Reservoir area; Seepage analysis; Underground powerhouse; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/170/2/022025/pdf DOI : 10.1088/1755-1315/170/2/022025 |
|
学科分类:环境科学(综合) | |
来源: IOP | |
【 摘 要 】
The 3D finite element gird grid for whole pumped storage power station project area is set up. The seepage analysis shows the potential distribution for seepage field is clear and well. The leakage water flow form upper reservoir basin rack mass to underground powerhouse, and then to the lower river. The leakage has little influence on the hydrogeological conditions in the reservoir area. The anti-seepage and drainage measures is technically reasonable for upper reservoir. The permeability stability for upper and lower reservoir is acceptable. And grouting should be strengthened for the mountain in right dam shoulder should, if necessary according to geological conditions.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Large scale 3D seepage analysis of whole pumped storage power station project area | 224KB | download |