会议论文详细信息
Asian Working Group- IAHR's Symposium on Hydraulic Machinery and Systems
Study on improvement of hump characteristic of an axial flow axial pump by grooving inlet wall
Yang, K.F.^1 ; Feng, J.J.^1 ; Zhu, G.J.^1 ; Lu, J.L.^1 ; Luo, X.Q.^1
Institute of Water Resources and Hydro-electric Engineering, Xi'An University of Technology, Xi'an
710048, China^1
关键词: Axial flow pump;    Axial grooves;    Design flow rate;    Hump characteristic;    Incidence angles;    Part load conditions;    Pump impeller;    Small flow-rate;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/163/1/012090/pdf
DOI  :  10.1088/1755-1315/163/1/012090
来源: IOP
PDF
【 摘 要 】
When operating at part load conditions, flow separations may occur in the impeller of an axial flow pump due to the increase of the incidence angle at the impeller leading edge, probably resulting in instability in head curve. In this paper, the hump characteristic in head curve of an axial flow pump has been examined by CFD method with the help of ANSYS CFX 16.0. The results show that the head of the axial flow pump in the hump area decreased by 40% at 61% of the design flow rate, caused by stalls in the pump impeller. Furthermore, the improvement of head curve has been conducted by applying axial grooves at the wall of the pump inlet section. It is found that under the condition of small flow rates, the axial groove can effectively reduce the inlet circulation and the attack angle at the leading edge of the impeller. As a result, the back flow on the suction side of the impeller has been reduced. Consequently, the hump phenomenon in the head curve of the axial flow pump has been effectively eliminated.
【 预 览 】
附件列表
Files Size Format View
Study on improvement of hump characteristic of an axial flow axial pump by grooving inlet wall 964KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:28次