会议论文详细信息
2018 4th International Conference on Environment and Renewable Energy
Pollutants Emission Characteristics of an Ultra-low Coal-fired Power Unit
生态环境科学;能源学
Bing, Li^1 ; Yongqiang, Song^2 ; Qilong, Zhang^1 ; Can, Zhou^1 ; Haoran, Duan^1
Shandong Branch of Huadian Electric Power Research Institute, Jinan, China^1
Huadian Power International Corporation Limited Zouxian Power Plant, Jining, China^2
关键词: Coal-fired power plant;    Coal-fired power unit;    Low emission;    Particulate Matter;    Pollutants emissions;    Pollution control devices;    Removal efficiencies;    Well control;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/159/1/012014/pdf
DOI  :  10.1088/1755-1315/159/1/012014
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

The concentration of particulate matter (PM), SO2, NOx, SO3, HCl, HF, and PM2.5 were measured in a 330MW ultra low emission coal-fired power unit. The pollutants emission characteristics and the effect of the conventional pollution control devices on non-conventional pollutants were investigated. The test results show that the concentration of NOx, SO2and PM are 26.9 mg/m3, 18.1 mg/m3, 2.9 mg/m3respectively. The coal-fired power plant, equipped with WFGD and WESP could well control SO3, HCl, HF, and PM2.5 emission from the flue gas. SO3removal efficiency of WFGD and WESP are 42.2% and 82.8% respectively. HCl and HF removal efficiency by WFGD are 90.8% and 91.5% respectively. PM2.5 removal efficiency of WESP is 86.9%.

【 预 览 】
附件列表
Files Size Format View
Pollutants Emission Characteristics of an Ultra-low Coal-fired Power Unit 356KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:19次