2018 2nd International Workshop on Renewable Energy and Development | |
Analysis of Slab-column Shearwall Structure of 6000 Tons Cold Storage | |
能源学;经济学 | |
He, Dongqing^1 ; Song, Pengwei^1 ; Jie, Pengyu^1 | |
Laboratory for Recycled and Functional Building Materials, Henan University, Kaifeng (Henan) | |
475004, China^1 | |
关键词: Analysis and calculations; External wall insulations; Functional requirement; Load characteristics; Overall stabilities; Overall stiffness; Seismic Performance; Shear-wall structures; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/153/5/052013/pdf DOI : 10.1088/1755-1315/153/5/052013 |
|
来源: IOP | |
【 摘 要 】
Combining with the functional requirements, the site conditions and the 6000 tons load characteristics of cold storage, so determine its structure system for the slab-column-shear wall structure. The paper recommends the design of foundation, the settings of column cap, the arrangement of shear wall, the punching shear of floor slab and the analysis and calculation results of main structure. By addition shear wall in slab-column structure to increase the overall stiffness of structure and improve the seismic performance of structure. Take the detached form between the main structure and the external wall insulation, while set anchorage beam between in the main floor and the ring beam along the axis of the column grid to enhance the overall stability of the external wall insulation.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Analysis of Slab-column Shearwall Structure of 6000 Tons Cold Storage | 694KB | download |