会议论文详细信息
2018 2nd International Conference on Environmental and Energy Engineering
Effect of Flue Gas Recirculation on Reheated Steam Temperature of a 1000MW Ultra-supercritical Double Reheat Boiler
生态环境科学;能源学
Ma, K.^1 ; Li, C.F.^1 ; Yan, W.P.^1 ; Sun, J.W.^2 ; Cai, P.^2 ; Huang, Q.L.^2
MOE's Key Lab of Condition Monitoring and Control for Power Plant Equipment, School of Energy and Power Engineering, North China Electric Power University, Baoding, China^1
Nanjing Inspection Centerof Quality Performance for Electric Equipment, Nanjing, China^2
关键词: Boiler efficiency;    Boiler operations;    Boiler thermodynamic calculation;    Double reheat;    Economizer outlet;    Flue gas recirculation;    Reheat steam temperature;    Steam temperature;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/146/1/012043/pdf
DOI  :  10.1088/1755-1315/146/1/012043
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

In view of the problem that the reheat steam temperature is lower than the design value in the operation of a 1000MW ultra-supercritical double reheat boiler in a power plant, this paper puts forward the method of flue gas recirculation (FGR) to improve it. Two schemes are put forward:the extraction of flue gas from the economizer or the draft fan to the bottom burner of the furnace. Indifferentload conditions,using the standard method of boiler thermodynamic calculation,the influence of different FGR schemes on boiler operation parameters is calculated. The results show that above FGR schemescan obviously improve thereheat steam temperature; with the increase of the amount of recirculating gas, the rise of the reheat steam temperature increases; with the decrease of the load, the influence of FGR on steam temperature increase; the scheme of extracting recirculating flue gas from the economizer outlet has little effect on the boiler efficiency, which is more suitable for the boiler, and the reasonableFGR rate is about 10%.

【 预 览 】
附件列表
Files Size Format View
Effect of Flue Gas Recirculation on Reheated Steam Temperature of a 1000MW Ultra-supercritical Double Reheat Boiler 373KB PDF download
  文献评价指标  
  下载次数:10次 浏览次数:28次