会议论文详细信息
2018 2nd International Conference on Environmental and Energy Engineering
Measurement and Evaluation of Residual Disinfection by Products in Tap Water from Xiamen
生态环境科学;能源学
Xiajing, Lin^1 ; Aili, Yang^1 ; Fuxiang, Chen^1
Xiamen University of Technology, College of Environmental Science and Engineering, Xiamen
361024, China^1
关键词: Disinfection by-product;    Industrial area;    Industrial zones;    National standard;    Tap water;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/146/1/012015/pdf
DOI  :  10.1088/1755-1315/146/1/012015
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

This paper has tested typical anions including F-, Cl-, NO3-, BrO3-, ClO-, SO42-.in tap water from Xiamen in order to understand the residual status of disinfection byproducts. Ion chromatography is used to analyze anionsconcentrations from residential and industrial zones in six Districts of Xiamen. The results demonstrate that: (1)BrO3-is not detected in all samples, (2) NO3-and SO42-exceed 4.046mg/L and 2.223mg/L, the peakconcentrations are 14.342mg/L and 39.345mg/L, respectively, (3) NO3-and SO42-are quite high in Haicang, Siming and Huli districts, which exceed 14.031mg/L and 36.708mg/L, respectively, (4) Smallerresidual disinfection byproductsare found in the tap water near the industrial areas of Jimei, Tongan and Xiangan Districts compared to other districs, all criteria meet the national standard, which means water quality is in a good condition in these three areas.

【 预 览 】
附件列表
Files Size Format View
Measurement and Evaluation of Residual Disinfection by Products in Tap Water from Xiamen 380KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:17次