| 2017 6th International Conference on Power Science and Engineering | |
| Efficiency assessment of bi-radiated screens and improved convective set of tubes during the modernization of PTVM-100 tower hot-water boiler based on controlled all-mode mathematic models of boilers on Boiler Designer software | |
| Orumbayev, R.K.^1 ; Kibarin, A.A.^1 ; Khodanova, T.V.^1 ; Korobkov, M.S.^1 | |
| Heat Power Plants Department, Non-profit JSC 'Almaty University of Power Engineering and Telecommunications', Almaty | |
| 050013, Kazakhstan^1 | |
| 关键词: Boiler operations; Boiler units; Efficiency assessment; Heat production; Hot water boilers; Long term production; Mathematic model; Operation reliability; | |
| Others : https://iopscience.iop.org/article/10.1088/1755-1315/136/1/012016/pdf DOI : 10.1088/1755-1315/136/1/012016 |
|
| 来源: IOP | |
PDF
|
|
【 摘 要 】
This work contains analysis of technical values of tower hot-water boiler PTVM-100 when operating on gas and oil residual. After the test it became clear that due to the construction deficiency during the combustion of oil residual, it is not possible to provide long-Term production of heat. There is also given a short review on modernization of PTVM-100 hot-water boilers. With the help of calculations based on controlled all-mode mathematic modules of hot-water boilers in BOILER DESIGNER software, it was shown that boiler modernization by use of bi-radiated screens and new convective set of tubes allows decreasing sufficiently the temperature of combustor output gases and increase reliability of boiler operation. Constructive changes of boiler unit suggested by authors of this work, along with increase of boiler's operation reliability also allow to improve it's heat production rates and efficiency rate up to 90,5% when operating on fuel oil and outdoor installation option.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Efficiency assessment of bi-radiated screens and improved convective set of tubes during the modernization of PTVM-100 tower hot-water boiler based on controlled all-mode mathematic models of boilers on Boiler Designer software | 1339KB |
PDF