| 2018 Asia Conference on Energy and Environment Engineering | |
| Energy Saving Performance Analysis of An Inverter-based Regenerative Power Re-utilization Device for Urban Rail Transit | |
| 能源学;生态环境科学 | |
| Li, Jin^1 ; Qiu, Zhiling^1 ; Hu, Leilei^1 | |
| Nanjing APAITEK Technology Co. Ltd, Nanjing | |
| 210000, China^1 | |
| 关键词: Absorption model; Key influencing factors; Performance analysis; Performance data; Power absorption; Regenerative energy; Regenerative power; Urban rail transit; | |
| Others : https://iopscience.iop.org/article/10.1088/1755-1315/133/1/012008/pdf DOI : 10.1088/1755-1315/133/1/012008 |
|
| 学科分类:环境科学(综合) | |
| 来源: IOP | |
PDF
|
|
【 摘 要 】
The inverter-based regenerative braking power utilization devices can re-utilize the regenerative energy, thus reduce the energy consumption of urban rail transit. In this paper the power absorption principle of the inverter-based device is introduced, then the key influencing factors of energy saving performance are analyzed based on the absorption model. The field operation data verified that the control DC voltage plays an important role and lower control DC voltage yields more energy saving. Also, the one year energy saving performance data of an inverter-based re-utilization device located in NanJing S8 line is provided, and more than 1.2 million kWh energy is recovered in the one year operation.
【 预 览 】
| Files | Size | Format | View |
|---|---|---|---|
| Energy Saving Performance Analysis of An Inverter-based Regenerative Power Re-utilization Device for Urban Rail Transit | 1097KB |
PDF