3rd International Conference on Energy Equipment Science and Engineering | |
Evaluation of two typical distributed energy systems | |
Han, Miaomiao^1 ; Tan, Xiu^1 | |
Huadian Electric Power Research Institute Co. Ltd., West Lake Science and Technology Economic, Zone Road No.10, Hangzhou | |
310030, China^1 | |
关键词: Calculation results; Distributed energies; Distributed energy systems; Efficiency index; Environmental requirement; Load factors; Second laws of thermodynamics; | |
Others : https://iopscience.iop.org/article/10.1088/1755-1315/128/1/012181/pdf DOI : 10.1088/1755-1315/128/1/012181 |
|
来源: IOP | |
【 摘 要 】
According to the two-natural gas distributed energy system driven by gas engine driven and gas turbine, in this paper, the first and second laws of thermodynamics are used to measure the distributed energy system from the two parties of "quantity" and "quality". The calculation results show that the internal combustion engine driven distributed energy station has a higher energy efficiency, but the energy efficiency is low; the gas turbine driven distributed energy station energy efficiency is high, but the primary energy utilization rate is relatively low. When configuring the system, we should determine the applicable natural gas distributed energy system technology plan and unit configuration plan according to the actual load factors of the project and the actual factors such as the location, background and environmental requirements of the project. "quality" measure, the utilization of waste heat energy efficiency index is proposed.
【 预 览 】
Files | Size | Format | View |
---|---|---|---|
Evaluation of two typical distributed energy systems | 287KB | download |