会议论文详细信息
2017 3rd International Conference on Environmental Science and Material Application
Comparison and applicability analysis of models for estimating radiological dose rates of freshwater biota
生态环境科学;材料科学
Zhang, Xiaofeng^1 ; Yang, Zongzhen^1 ; Qin, Chunli^1
Suzhou Nuclear Power Research Institute, Suzhou
215004, China^1
关键词: Applicability analysis;    Effluent discharge;    Estimation results;    Intercomparisons;    Non-human biotas;    Radiation assessment;    Radiological dose;    Radiological impacts;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/108/4/042040/pdf
DOI  :  10.1088/1755-1315/108/4/042040
来源: IOP
PDF
【 摘 要 】

A number of inter-comparisons of non-human biota radiation assessment models have been fulfilled by international researchers and organizations. This paper describes the radiological impact to reference biota in Chinese inland nuclear power plant scenario, by using RESRAD-Biota, ERICA and R&D 128. The estimation results are ranging from 6.1×10-3μGy/h to 6.17×10-2μGy/h, mainly contributed by134Cs and137Cs, obviously below recommended limits and thus prove the biota in reservoir can be adequately protected from effluent discharge. By comparing models characteristics and performances in exercise, we conclude the ERICA tool reveals more applicability in Chinese nuclear sites and propose several suggestions to establish native framework for non-human biota assessment.

【 预 览 】
附件列表
Files Size Format View
Comparison and applicability analysis of models for estimating radiological dose rates of freshwater biota 211KB PDF download
  文献评价指标  
  下载次数:6次 浏览次数:19次