会议论文详细信息
2nd international Tropical Renewable Energy Conference 2017
Effect of graphenenano-fluid on heat pipe thermal performance for passive heat removal in nuclear spent fuel storage pool
Rosidi, Ainur^1,2 ; Putra, Nandy^1 ; Kusuma, Mukhsinun Hadi^1,2
Heat Transfer Laboratory, Department of Mechanical Engineering, Universitas Indonesia, Depok
16424, Indonesia^1
Centre for Nuclear Reactor Safety and Technology, National Nuclear Energy Agency of Indonesia (BATAN), Kawasan Puspiptek Serpong, Tangerang Selatan
15314, Indonesia^2
关键词: Experimental investigations;    Nuclear power reactors;    Nuclear spent fuels;    Passive heat removal;    Station blackout;    Thermal Performance;    Transfer phenomenon;    Volumetric flow rate;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/105/1/012030/pdf
DOI  :  10.1088/1755-1315/105/1/012030
来源: IOP
PDF
【 摘 要 】

After Fukushima Dai-ichi nuclear power reactor accident, spent fuel in spent fuel storage pool (SFSP) became an important thing to pay attention to, due to its decay heat release. If station blackout occurred, the active system for SFSP cooling system will experience malfunction to remove the product of decay heat. To keep spent fuel safe, heat pipe as passive cooling system device can be used to remove spent fuel decay heat even if the active cooling system failed. Heat pipe with 6 m on length will be proposed as apassive cooling system in SFSP. For that, it is necessary to analyze the effect of Graphene nano-fluid as heat pipe working fluid. The objective of this research is to know the effect on Graphene nano-fluid to enhance the heat pipe thermal performance and to know the heat transfer phenomena inside the heat pipe based on Graphene nano-fluid. Graphene nano-fluid with 1% weight concentration was used as working fluid with filling ratio of 80%. The experimental investigation is conducted with varying the evaporator heat load of 1000, 1500, 2000, and 2500 W. Water as coolant flows in thecondenser with aconstant volumetric flow rate of 8 L/min. The experiment results show that there was anovershoot, zigzag and stable phenomena inside the heat pipe. The thermal resistance of heat pipe is obtained at 0.015 °C/W. The use of Graphene nano-fluid as working fluid can enhance the heat pipe thermal performance significantly and can be used as an alternative working fluid in heat pipe for thepassive cooling system in SFSP of nuclear power plant.

【 预 览 】
附件列表
Files Size Format View
Effect of graphenenano-fluid on heat pipe thermal performance for passive heat removal in nuclear spent fuel storage pool 654KB PDF download
  文献评价指标  