会议论文详细信息
International Conference on Sustainability in Architectural Design and Urbanism 2017
The evaluation the magnitude radiation exposure dose rate in digital radiography room design
土木建筑工程;经济学
Dwiyanto, Agung^1 ; Budi, Wahyu Setia^2 ; Hardiman, Gagoek^1
Department of Architecture, Faculty of Engineering, Universitas Diponegoro, Semarang, Indonesia^1
Department of Physics, Faculty of Sciences and Mathematics, Universitas Diponegoro, Semarang, Indonesia^2
关键词: Computer modeling;    Digital radiography;    Dose rate;    External radiation exposure;    Measuring points;    Observation point;    Radiation Exposure;    Secondary radiations;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/99/1/012003/pdf
DOI  :  10.1088/1755-1315/99/1/012003
学科分类:土木及结构工程学
来源: IOP
PDF
【 摘 要 】
This study discusses the dose rate in digital radiography room, buit according to meet the provisions of KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation of BAPETEN No. 8 / 2011. The provisions primary concern of radiation safety, not comfort, by considering the space design. There are five aspects to consider in designing the space: functionality, comfort, security, movement activities and aesthetics. However provisions only met three aspects of the design, which are a function, security and movement activity. Therefore, it is necessary to evaluate digital radiography room in terms of its ability to control external radiation exposure to be safe and comfortable The dose rate is measured by the range of primary and secondary radiation in the observation points by using Surveymeter. All data are obtained by the preliminary survey prior to the study. Furthermore, the review of digital radiography room is done based on architectural design theory. The dose rate for recommended improvement room is recalculated using the same method as the actual room with the help of computer modeling. The result of dose rate calculation at the inner and outer part of digital radiography observation room shows that in-room dose for a week at each measuring point exceeds the allowable dose limit both for staff and public. During a week of observation, the outdoor dose at some measuring points exceeds the dose limit set by the KEMENKES No.1014 / Menkes / SK / XI / 2008 and Regulation BEPETEN No 8/2011. Meanwhile, the result of dose rate calculation in the inner and outer part of the improved digital radiography room can meet the applicable regulations better.
【 预 览 】
附件列表
Files Size Format View
The evaluation the magnitude radiation exposure dose rate in digital radiography room design 623KB PDF download
  文献评价指标  
  下载次数:16次 浏览次数:43次