会议论文详细信息
International Symposium on Resource Exploration and Environmental Science
Experimental study on temperature distribution of membrane water wall in an ultra-supercritical pressure once-through boiler burning zhundong coal
地球科学;生态环境科学
He, Honghao^1 ; Li, Wenjun^1 ; Zeng, Jun^1 ; Xie, Guohong^1 ; Peng, Min^1 ; Duan, Xuenong^1
State Grid Hunan Electric Power Corporation Research Institute, Changsha, China^1
关键词: Membrane water wall;    Once-through boilers;    Super-critical pressures;    Temperature deviation;    Temperature uniformity;    Working fluid;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/64/1/012092/pdf
DOI  :  10.1088/1755-1315/64/1/012092
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

Taking an ultra-supercritical pressure once-through boiler as an example, the temperature distribution of the lower membrane water wall is investigated experimentally, the conclusion reveals that increasing the proportion of Zhundong coal can effectively reduce the district heat load, which benefits the temperature uniformity in the lower membrane water wall. When the boiler being operated at middle load, the temperature deviation in lower membrane water wall increase simultaneously, one of the reasons is that the restriction orifice could not adjust the flow rate of working fluid as expected. By adjusting boiler performance, the temperature uniformity of lower membrane water wall can be improved to a certain degree.

【 预 览 】
附件列表
Files Size Format View
Experimental study on temperature distribution of membrane water wall in an ultra-supercritical pressure once-through boiler burning zhundong coal 442KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:8次