会议论文详细信息
2017 International Conference on Environmental and Energy Engineering
Discussion on Boiler Efficiency Correction Method with Low Temperature Economizer_Air Heater System
生态环境科学;能源学
Ke, Liu^1 ; Xing-Sen, Yang^1 ; Fan-Jun, Hou^2 ; Zhi-Hong, Hu^1
State Grid Shandong Electric Power Research Institute, Jinan
250003, China^1
Zhong Shi Yi Tong Group, Jinan
250003, China^2
关键词: Boiler efficiency;    Condensed water;    Correction method;    Exhaust gas temperatures;    Flue gas temperatures;    Gas temperature;    Low temperatures;    Reference values;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/63/1/012002/pdf
DOI  :  10.1088/1755-1315/63/1/012002
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

This paper pointed out that it is wrong to take the outlet flue gas temperature of low temperature economizer as exhaust gas temperature in boiler efficiency calculation based on GB10184-1988. What's more, this paper proposed a new correction method, which decomposed low temperature economizer-air heater system into two hypothetical parts of air preheater and pre condensed water heater and take the outlet equivalent gas temperature of air preheater as exhaust gas temperature in boiler efficiency calculation. This method makes the boiler efficiency calculation more concise, with no air heater correction. It has a positive reference value to deal with this kind of problem correctly.

【 预 览 】
附件列表
Files Size Format View
Discussion on Boiler Efficiency Correction Method with Low Temperature Economizer_Air Heater System 629KB PDF download
  文献评价指标  
  下载次数:7次 浏览次数:13次