会议论文详细信息
28th IAHR symposium on Hydraulic Machinery and Systems
Simulation of the transient processes of load rejection under different accident conditions in a hydroelectric generating set
Guo, W.C.^1,2 ; Yang, J.D.^1 ; Chen, J.P.^1 ; Peng, Z.Y.^1 ; Zhang, Y.^1 ; Chen, C.C.^1
State Key Laboratory of Water Resources and Hydropower Engineering Science, Wuhan University, Wuhan
430072, China^1
Maha Fluid Power Research Center, Department of Agricultural and Biological Engineering, Purdue University, West Lafayette
47907, United States^2
关键词: Dynamic characteristics;    Emergency distributing valves;    Hydro turbine governing systems;    Hydroelectric generating set;    Hydropower stations;    Hydroturbine governing system;    Numerical simulation method;    Power generation systems;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/49/5/052016/pdf
DOI  :  10.1088/1755-1315/49/5/052016
来源: IOP
PDF
【 摘 要 】

Load rejection test is one of the essential tests that carried out before the hydroelectric generating set is put into operation formally. The test aims at inspecting the rationality of the design of the water diversion and power generation system of hydropower station, reliability of the equipment of generating set and the dynamic characteristics of hydroturbine governing system. Proceeding from different accident conditions of hydroelectric generating set, this paper presents the transient processes of load rejection corresponding to different accident conditions, and elaborates the characteristics of different types of load rejection. Then the numerical simulation method of different types of load rejection is established. An engineering project is calculated to verify the validity of the method. Finally, based on the numerical simulation results, the relationship among the different types of load rejection and their functions on the design of hydropower station and the operation of load rejection test are pointed out. The results indicate that: The load rejection caused by the accident within the hydroelectric generating set is realized by emergency distributing valve, and it is the basis of the optimization for the closing law of guide vane and the calculation of regulation and guarantee. The load rejection caused by the accident outside the hydroelectric generating set is realized by the governor. It is the most efficient measure to inspect the dynamic characteristics of hydro-turbine governing system, and its closure rate of guide vane set in the governor depends on the optimization result in the former type load rejection.

【 预 览 】
附件列表
Files Size Format View
Simulation of the transient processes of load rejection under different accident conditions in a hydroelectric generating set 1169KB PDF download
  文献评价指标  
  下载次数:15次 浏览次数:28次