会议论文详细信息
12th TSAE International Conference
Number of blades of rotating blades affecting the boiling heat transfer enhancement of distilled water
Suriyawong, A.^1 ; Saisorn, S.^2 ; Kawahara, A.^3 ; Wongwises, S.^4
Department of Mechanical Engineering, Faculty of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok
10520, Thailand^1
Department of Engineering, King Mongkut's Institute of Technology Ladkrabang, Prince of Chumphon Campus, Pathiu District, Chumphon
86160, Thailand^2
Faculty of Advanced Science and Technology, Kumamoto University, Kumamoto, Japan^3
Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab. (FUTURE), Department of Mechanical Engineering, Faculty of Engineering, King Mongkut's University of Technology Thonburi, Bangmod, Bangkok
10140, Thailand^4
关键词: Boiling heat transfer enhancement;    Bubble nucleation;    Copper materials;    Heating surfaces;    Isolated bubbles;    Nucleate boiling heat transfers;    Nucleate pool boiling;    Photographic observation;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/301/1/012040/pdf
DOI  :  10.1088/1755-1315/301/1/012040
来源: IOP
PDF
【 摘 要 】

This study examined the nucleate pool boiling characteristics of distilled water attached to a heating surface with a horizontal circular plate above which the rotating blades were installed. The experiments were performed to explore the effects of number of blades as well as the visualization of pool boiling phenomena on nucleate boiling heat transfer characteristics. The rotating blades were made from copper material, with the number of blade of 2, 3 and 4 blades. The results showed that, the rotor with 4 blades yielded a higher heat transfer coefficient than those with 2 or 3 blades. This is because the increased number of blade provided more chance for the bubbles to strike the rotating blades. Hence, the rotating blades did create a commotion of the working fluid above the heating surface. Camera frames were captured using an Aos Promon Studio at the heat fluxes of about 160-610 kW/m2 to identify the location of bubble nucleation for each configuration. The photographic observations showed that, the pool boiling phenomenon with the heat flux value of about 160 kW/m2 corresponded to the isolated bubble, and the boiling characteristic with the heat flux value of about 610 kW/m2 were based on the column regime.

【 预 览 】
附件列表
Files Size Format View
Number of blades of rotating blades affecting the boiling heat transfer enhancement of distilled water 860KB PDF download
  文献评价指标  
  下载次数:12次 浏览次数:28次