会议论文详细信息
2019 5th International Conference on Energy Materials and Environment Engineering
Removal of tar from coke oven flue gas by emulsion liquid membrane
能源学;生态环境科学
Zhang, Junjie^1 ; Dong, Pengxiong^1 ; Li, Chunying^2 ; Li, Hongxia^1
Collage of Chemical Engineering, Collage of Life Science, College of Psychology, North China University of Science and Tecnology, 21Bohai Road, Caofeidian Xingcheng, Thangshan, Hebei
063210, China^1
Shenyang Environmental Monitoring Center, Shenyang
110015, China^2
关键词: Absorption time;    Emulsion liquid membrane (ELM);    Experimental conditions;    External phase;    Optimal operating conditions;    Optimum operating conditions;    Stirring speed;    Tar concentration;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/295/5/052023/pdf
DOI  :  10.1088/1755-1315/295/5/052023
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

The new method for removal tar from coke oven flue gas by emulsion liquid membrane was developed. The W/O emulsion was prepared by using kerosene as organic solvent, L-113B as surfactant, water as internal phase and external phase, respectively. The optimum operating conditions were obtained: The optimum experimental conditions of the ELM process for initial tar concentration of 62.5 mg/L are: absorption time: 40 min; concentration of L-113B: 4% (v/v); emulsification speed: 4000 r/min; volume ratio of emulsion to external water phase: 1:4; gas flow rate: 100 mL/min; stirring speed: 630 r/min; volume ratio of oil phase to internal phase: 1:1. The efficiency of tar removal was about 98 % at optimal operating conditions.

【 预 览 】
附件列表
Files Size Format View
Removal of tar from coke oven flue gas by emulsion liquid membrane 502KB PDF download
  文献评价指标  
  下载次数:8次 浏览次数:12次