Taking the main bridge of the shuidong bridge in Youxi country of Fujian province as background, this paper develops the static characteristic analysis and static load test study on long-span prestressed continuous rigid frame bridge with V-shaped pier. By the analysis and comparison between the measured data and FEA results, it evaluates the working condition of the bridge. The results show: Firstly,each evaluation indicator tested meets the requirements of "Test methods for large-span concrete bridges" Secondly, the strain efficacy coefficient of measured points in top plate of each control section is within 0.65∼0.74, and that of the measured points in bottom plate is within 0.64∼0.73, the residual strain of the measured points is less, therefore, the safety stock of the bridge is sufficient, and it is on the flexible working condition basically; Finally, the measured value and the theoretical value of deflection curves along the longitudinal bridge is compatible, the efficacy coefficient of vertical deformation is within 0.55∼0.85, and the severity of the practical structure is more.

【 预 览 】
附件列表
Files Size Format View
Static Load Test Study on Long-span Continuous Rigid Frame Bridge with V-shaped Pier 540KB PDF download