House-scale Renewable Energy System Sizing in Liverpool
能源学;生态环境科学
Suhendri^1 ; Handayani, Tri Pratiwi^2
Institut Teknologi Bandung, Indonesia^1
Universitas Muhammadiyah Gorontalo, Indonesia^2
关键词: Building integrated;    Electricity load;    Evacuated tube collectors;    Renewable energy systems;    Renewable energy technologies;    Resource assessments;    Rotor diameter;    Solar thermal;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/291/1/012028/pdf
DOI  :  10.1088/1755-1315/291/1/012028
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

Renewable energy technology such as solar thermal, PV, and wind have been developed to be building integrated. This exercise is aimed to sizing those three renewable energy systems for a typical house in the UK, specifically Liverpool. The methodologies used in this exercise are load evaluation, resource assessment, and finally sizing the systems. The results from all of sizing calculation show that there will be 6 evacuated tube collectors with 6m2 area, 14 PV modules with 20.7 m2 area, and 1 wind turbine with 2.5 rotor diameter. The renewable energy systems for electricity sized are predicted to cover 78.47% of the electricity load with PV contribution as many as 54.5% and the rest 24% is covered by wind turbine.

【 预 览 】
附件列表
Files Size Format View
House-scale Renewable Energy System Sizing in Liverpool 895KB PDF download