会议论文详细信息
2019 3rd International Workshop on Renewable Energy and Development
Finite Element Study on Shear Performances of In-filled Bolt Joint of Assembled GRC Wall with Light Steel Skeleton Frame
能源学;生态环境科学
Tang, Zhirong^1 ; Zha, Xiaoxiong^1 ; Wang, Baolin^2
School of Civil and Environmental Engineering, Harbin Institute of Technology, Shenzhen, Guangdong
GD 755, China^1
School of Science, Harbin Institute of Technology, Shenzhen, Guangdong
GD 755, China^2
关键词: Elastic-plastic behaviour;    Finite-element study;    Fracture failure;    Glass fiber reinforced concrete;    Loading process;    Shear performance;    Software ABAQUS;    Steel skeleton;   
Others  :  https://iopscience.iop.org/article/10.1088/1755-1315/267/4/042094/pdf
DOI  :  10.1088/1755-1315/267/4/042094
学科分类:环境科学(综合)
来源: IOP
PDF
【 摘 要 】

A new in-filled wall is used in assembled steel structure buildings, which consists of two layers of glass fiber reinforced concrete (GRC) panels and a built-in light steel skeleton frame. To make this new wall fill in the main steel structure, a new in-filled bolt joint is used. In order to obtain the mechanical properties and failure modes under shear load, the shear performances of this joint were studied with the finite element (FE) software ABAQUS. The results show that before reaching the fracture failure strain, the in-filled bolt joint shows good elastic-plastic behaviour. When the strain of the in-filled bolt joint reaches the failure strain, the shear load reaches the peak value. Subsequently, due to the shear fracture of the bolt, the shear load drops rapidly. Throughout the loading process, the stress of steel beam and rectangular steel tube is always very small and the stress of the joint yields in a large area in the later stage.

【 预 览 】
附件列表
Files Size Format View
Finite Element Study on Shear Performances of In-filled Bolt Joint of Assembled GRC Wall with Light Steel Skeleton Frame 813KB PDF download
  文献评价指标  
  下载次数:21次 浏览次数:60次